FC0002 Joint Module Fault Alarm and Protection Logic Guide
| Item | Details |
|---|---|
| Document Number | FC0002 |
| Revision | Rev. 1.0.1 |
| Applicable Products | JxServo Joint Module / Integrated Communication Module |
| Applicable Firmware | Delivery firmware supporting V2.0 diagnostic IDs |
| Language | English |
| Last Updated | 2026-07-30 |
This guide explains the Warning (WARN), Fault (FLT), and Trip (TRIP) events that a Joint Module may report during operation, together with their corresponding protection actions, clearing methods, and field troubleshooting procedures.
Different product models, hardware platforms, and delivery firmware builds may enable only a subset of these diagnostic items, and their thresholds, confirmation times, protection actions, and hardware signal wiring may also vary. Values listed in this document represent common reference configurations; in actual deployment, refer to the release documentation, delivery firmware, and device parameters of your specific product model.
After a FAULT or TRIP occurs, never repeatedly clear faults or force servo Enable while the underlying cause remains present. First bring the equipment to a safe state, eliminate power supply, wiring, mechanical binding, overload, or feedback anomalies, then execute a fault reset, and verify operation starting from no-load, low-speed conditions.
1. Fault Code Reading and Encoding Rules
The lower 16 bits of a V2.0 diagnostic ID follow the 0xDDSS format:
DD: Fault domain, distinguishing categories such as power, drive/current, sensor, control, and communication.SS: Fault sub-item, identifying the specific anomaly within that fault domain.- Example:
0x0507denotes fault domain0x05and sub-item0x07, corresponding to "Excessive velocity tracking error".
When reading fault information over CANopen:
0x603F:00reads the currently active or actually transmitted CANopen error code.0x4500:00reads the lower 16 bits of the V2.0 diagnostic ID for the most recent warning or fault.- The
0x80 + NodeIDEmergency (EMCY) Frame also carries severity and snapshot context data for analyzing actual trigger values, thresholds, or hardware flags.
For complete SDO frame formats, Emergency (EMCY) Frame parsing, and legacy compatibility code mappings, refer to FC0001 V2.0 Fault Code Encoding and SDO Reading Guide.
2. Fault Severity Levels and Protection Actions
2.1 Fault Severity Levels
| Level | Meaning | Typical Handling |
|---|---|---|
Warning (WARN) | Abnormal trend or operating quality issue | Logged as a warning; the fault manager does not actively stop the drive |
Fault (FAULT) | Anomaly affecting safety or control reliability | Executes configured protection action; reset after eliminating the root cause |
Trip (TRIP) | Severe anomaly in hardware or critical feedback link | Immediately stops motion output and enters latched fault protection |
2.2 Protection Actions and Clearing Modes
| Type | Meaning |
|---|---|
Log Only (ACT_REC) | Logs the warning without actively altering servo output |
Controlled Stop / Hold (ACT_DSTOP / ACT_DHOLD) | Decelerates to a stop along a configured ramp, then shuts off output, engages the brake, or holds position depending on hardware configuration |
Emergency Stop (ACT_ESTOP) | Revokes servo Enable and stops motion output, executing power-stage shutoff and brake engagement per hardware configuration |
Auto Clear (CLR_AUTO) | Automatically clears once the abnormal condition disappears and recovery criteria are satisfied |
Host Reset (CLR_HOST) | Cleared via fault reset from the host application or master controller after eliminating the cause and ensuring the servo is Disabled |
3. General Handling Workflow
- Record the diagnostic code along with load, speed, supply voltage, motor temperature, and ambient operating conditions at the time of occurrence.
- Locate the fault in the Quick Index below, then inspect its trigger conditions and troubleshooting recommendations under the corresponding fault domain.
- Prioritize ruling out hardware issues such as short circuits, wiring faults, power supply anomalies, mechanical overload, poor heat dissipation, brake issues, encoders, and sensors.
- Confirm that the trigger condition has been eliminated and ensure the servo is Disabled.
- Issue a "Clear Fault / Fault Reset" command from the host tool or master controller; power-cycle or recalibrate when explicitly required by the fault item.
- After a successful reset, test under no-load and low-speed conditions first before gradually returning to normal operating loads.
4. Fault Code Quick Index
| Fault Code | Fault Name | Level | Typical Protection Action |
|---|---|---|---|
0x0001 | Electrical angle zero not calibrated | FAULT | Emergency Stop |
0x0100 | DC bus overvoltage | FAULT | Emergency Stop |
0x0101 | DC bus undervoltage | FAULT | Emergency Stop |
0x0102 | DC bus hardware overvoltage trip | TRIP | Emergency Stop |
0x0103 | DC bus hardware overcurrent trip | TRIP | Emergency Stop |
0x0200 | Software overcurrent (Iq over-limit) | FAULT | Emergency Stop |
0x0201 | Phase U hardware overcurrent | TRIP | Emergency Stop |
0x0203 | Phase V hardware overcurrent | TRIP | Emergency Stop |
0x0204 | Drive over-temperature warning | WARN | Log Only |
0x0205 | Drive over-temperature fault | FAULT | Emergency Stop |
0x0206 | Phase U software overcurrent | TRIP | Emergency Stop |
0x0207 | Phase V software overcurrent | TRIP | Emergency Stop |
0x0302 | Motor over-temperature warning | WARN | Log Only |
0x0303 | Motor over-temperature fault | FAULT | Emergency Stop |
0x0400 | Encoder update timeout | TRIP | Emergency Stop |
0x0401 | Encoder read failure | WARN | Log Only |
0x0402 | Torque communication fault | FAULT | Controlled Stop |
0x0403 | Torque signal fault | FAULT | Controlled Stop |
0x0404 | Torque plausibility fault | FAULT | Controlled Stop |
0x0406 | Encoder status warning | WARN | Log Only |
0x0407 | Encoder status error | FAULT | Emergency Stop |
0x0408 | Current offset calibration failure | FAULT | Emergency Stop |
0x0500 | Excessive position tracking error | WARN | Log Only |
0x0501 | Torque control fault | FAULT | Emergency Stop |
0x0507 | Excessive velocity tracking error | FAULT | Emergency Stop |
0x0508 | Software stall | FAULT | Emergency Stop |
0x0509 | Velocity command exceeds upper limit | WARN | Log Only |
0x050A | Runaway / overspeed protection | FAULT | Emergency Stop |
0x050B | Excessive current tracking error | FAULT | Emergency Stop |
0x0600 | Communication heartbeat lost | WARN | Project-configurable |
0x0603 | CAN communication BusOff | WARN | Log Only |
0x0705 | Positive optical limit exceeded | FAULT | Emergency Stop |
0x0706 | Negative optical limit exceeded | FAULT | Emergency Stop |
0x0707 | Positive software limit exceeded | FAULT | Emergency Stop |
0x0708 | Negative software limit exceeded | FAULT | Emergency Stop |
5. Detailed Protection Logic
5.1 System and Calibration 0x00
0x0001 Electrical Angle Zero Not Calibrated
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | At power-up or before entering closed-loop control, the electrical angle zero parameter is detected as invalid, missing, or uncalibrated. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration, entering fault protection state. |
| Clearing Method | Complete electrical angle zero calibration and save parameters, ensure the servo is Disabled, then execute a fault reset or power-cycle the device. |
| Troubleshooting | Check whether initial assembly calibration was completed, whether parameters were saved properly, whether the parameter Flash region is intact, and whether firmware matches parameter version. |
5.2 DC Bus and Power Supply 0x01
0x0100 DC Bus Overvoltage
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | DC bus voltage exceeds the project threshold continuously for the confirmation duration; a typical reference setting is ≥ 68 V for ≥ 10 ms. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Check whether input supply voltage is too high, whether rapid deceleration causes regenerative voltage rise, power supply regeneration absorption capacity, bus capacitance, and braking circuitry. |
0x0101 DC Bus Undervoltage
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | DC bus voltage drops below the project threshold continuously for the confirmation duration; common reference thresholds are 40 V for 48 V modules and 20 V for 24 V modules, typically confirmed over 2 ms. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Check for supply voltage sag, insufficient PSU power rating, cable voltage drop, connector contact resistance, and power-up sequencing; measure actual DC bus voltage at the module terminals. |
0x0102 DC Bus Hardware Overvoltage Trip
| Item | Description |
|---|---|
| Level | Trip (TRIP) |
| Trigger Condition | Hardware overvoltage comparator or protection signal triggered; this hardware event bypasses normal software debounce timers. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Inspect supply surges, regenerative voltage spikes, comparator threshold hardware, and noise on protection lines. Independent reporting depends on whether the delivery hardware wires this dedicated comparator signal. |
0x0103 DC Bus Hardware Overcurrent Trip
| Item | Description |
|---|---|
| Level | Trip (TRIP) |
| Trigger Condition | Power stage hardware BRK or overcurrent comparator triggered and reported via platform interrupt. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Inspect for phase-to-phase or phase-to-ground shorts, severe mechanical shock loads, damaged power MOSFETs, current sensing faults, or comparator noise. Some platforms report this unified code without distinguishing Phase U/V. |
5.3 Drive, Current, and Power Stage 0x02
0x0200 Software Overcurrent (Iq Over-Limit)
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | Software detects Iq current exceeding the project threshold continuously; reference configuration is 95% of peak phase current for 50 ms. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Disabled by default in many standard projects. When enabled, inspect mechanical overload, current-loop gains, step command transients, and current sensing accuracy. |
0x0201 Phase U Hardware Overcurrent
| Item | Description |
|---|---|
| Level | Trip (TRIP) |
| Trigger Condition | Drive hardware BRK protection triggered and identified by the hardware platform specifically as Phase U overcurrent. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Inspect Phase U wiring, winding insulation, power MOSFETs, current-sense circuitry, hardware comparators, and mechanical shock. Platforms without per-phase comparator identification report 0x0103 instead. |
0x0203 Phase V Hardware Overcurrent
| Item | Description |
|---|---|
| Level | Trip (TRIP) |
| Trigger Condition | Drive hardware BRK protection triggered and identified by the hardware platform specifically as Phase V overcurrent. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Inspect Phase V wiring, winding insulation, power MOSFETs, current-sense circuitry, hardware comparators, and mechanical shock. Platforms without per-phase comparator identification report 0x0103 instead. |
0x0204 Drive Over-Temperature Warning
| Item | Description |
|---|---|
| Level | Warning (WARN) |
| Trigger Condition | Drive PCB or MOSFET temperature reaches the warning threshold continuously for the confirmation sample count; reference threshold is 90 °C over 2000 diagnostic samples. |
| Protection Action | Logs the warning only; the fault manager does not actively alter servo output. |
| Clearing Method | Clears automatically once temperature drops and satisfies auto-recovery hysteresis criteria. |
| Troubleshooting | Reduce load duty cycle and ambient temperature; inspect heatsink mounting, thermal interface material, airflow, and NTC sensor readings. Derating load proactively during the warning stage is recommended. |
0x0205 Drive Over-Temperature Fault
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | Drive PCB or MOSFET temperature reaches the fault threshold continuously; reference threshold is 110 °C confirmed over 200 ms. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Active fault status clears automatically once temperature cools below recovery threshold; after stopping, a fresh servo Enable command is still required to resume motion. |
| Troubleshooting | Check sustained overload, aggressive acceleration/deceleration duty cycles, thermal mounting, ambient temperature, and temperature sensing. Do not repeatedly force servo Enable before the drive has cooled down. |
0x0206 Phase U Software Overcurrent
| Item | Description |
|---|---|
| Level | Trip (TRIP) |
| Trigger Condition | Triggers immediately upon entry into the software Phase U instantaneous overcurrent check. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Check Phase U current sensing, phase short circuits, drive power stage, and current-loop gains. Independent reporting depends on the delivery platform and firmware build. |
0x0207 Phase V Software Overcurrent
| Item | Description |
|---|---|
| Level | Trip (TRIP) |
| Trigger Condition | Triggers immediately upon entry into the software Phase V instantaneous overcurrent check. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Check Phase V current sensing, phase short circuits, drive power stage, and current-loop gains. Independent reporting depends on the delivery platform and firmware build. |
5.4 Motor Temperature 0x03
0x0302 Motor Over-Temperature Warning
| Item | Description |
|---|---|
| Level | Warning (WARN) |
| Trigger Condition | Motor temperature reaches the warning threshold continuously for the confirmation sample count; reference threshold is 90 °C over 2000 diagnostic samples. |
| Protection Action | Logs the warning only; the fault manager does not actively alter servo output. |
| Clearing Method | Clears automatically once temperature drops and satisfies auto-recovery hysteresis criteria. |
| Troubleshooting | Reduce load torque or phase current; inspect mechanical friction, ambient cooling, motor thermistor wiring, and thermal parameters. Avoid sustained heavy-load operation while the warning remains active. |
0x0303 Motor Over-Temperature Fault
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | Motor temperature reaches the fault threshold continuously; reference threshold is 110 °C confirmed over 200 ms. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Active fault status clears automatically once temperature cools below recovery threshold; after stopping, a fresh servo Enable command is still required to resume motion. |
| Troubleshooting | Inspect mechanical binding, sustained overload, phase current levels, holding brake release state, heat dissipation conditions, and temperature sensor health. Allow the motor to cool thoroughly before resuming test runs. |
5.5 Encoder, Torque Sensor, and Sampling 0x04
0x0400 Encoder Update Timeout
| Item | Description |
|---|---|
| Level | Trip (TRIP) |
| Trigger Condition | Encoder consecutively fails to produce valid position updates, or the fast protection path determines position feedback is unavailable. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Check encoder connectors at both ends, sensor power supply, and signal integrity; replace the encoder if necessary. This trip indicates loss of a critical closed-loop feedback path. |
0x0401 Encoder Read Failure
| Item | Description |
|---|---|
| Level | Warning (WARN) |
| Trigger Condition | The encoder adaptation layer detects read failures or invalid packets reaching the configured confirmation count. |
| Protection Action | Logs the warning only; the fault manager does not actively alter servo output. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Check sensor power, cable shielding, interface timing, and signal integrity. Independent reporting depends on the encoder driver; persistent severe failures escalate to 0x0400. |
0x0402 Torque Communication Fault
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | With torque sensor monitoring enabled, no new valid frame is received consecutively or raw sensor data remains stale; reference setting is 15 consecutive confirmations. |
| Protection Action | Executes controlled deceleration stop; engages brake or shuts off output once stopped per hardware configuration, or adapts to decelerate-and-hold on brakeless modules. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Enabled only on models equipped with a torque sensor. Inspect sensor power, communication harness, interface configuration, data refresh rate, and main MCU task scheduling. |
0x0403 Torque Signal Fault
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | Torque feedback exhibits NaN, over-range readings, or abnormal bidirectional spikes; reference full-scale check is 300 N·m, with spike thresholds scaled to the protection limit. |
| Protection Action | Executes controlled deceleration stop; engages brake or shuts off output once stopped per hardware configuration, or adapts to decelerate-and-hold on brakeless modules. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Enabled only on models equipped with a torque sensor. Inspect zero-offset drift, mechanical sensor overload, connector contact, EMI noise, and torque calibration parameters. |
0x0404 Torque Plausibility Fault
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | Torque feedback plausibility check event triggers and reaches confirmation criteria. |
| Protection Action | Executes controlled deceleration stop; engages brake or shuts off output once stopped per hardware configuration, or adapts to decelerate-and-hold on brakeless modules. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Typically disabled by default and retained for protocol compatibility. When enabled, inspect consistency across torque estimation sources, zero offset, scale factor, and mechanical sensor mounting. |
0x0406 Encoder Status Warning
| Item | Description |
|---|---|
| Level | Warning (WARN) |
| Trigger Condition | Encoder hardware status word or driver adaptation layer reports a recoverable warning condition. |
| Protection Action | Logs the warning only; the fault manager does not actively alter servo output. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Depending on encoder type, inspect sensor supply voltage, magnetic ring field strength or air gap, temperature, internal status bits, and communication signal quality. Independent reporting depends on encoder driver support. |
0x0407 Encoder Status Error
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | Encoder hardware status word or driver adaptation layer reports a critical error rendering position feedback untrustworthy. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; triggers again if the encoder error bit remains asserted. |
| Troubleshooting | Inspect the encoder IC, magnetic ring or optical disk mounting, power supply, and communication link. Independent reporting depends on encoder driver support. |
0x0408 Current Offset Calibration Failure
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | Following power-on current zero-offset calibration, Phase U/V ADC offset exceeds the permissible window or exhibits excessive variance, inhibiting normal operation. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate current-sense hardware anomalies while ensuring zero motor current, rerun offset calibration or power-cycle the module, and clear the fault once calibration succeeds. |
| Troubleshooting | Inspect shunt resistors, current-sense op-amps, ADC reference voltage, bias network, solder joints, and EMI noise; ensure no drive PWM output or external back-EMF current is present during calibration. |
5.6 Control and Motion 0x05
0x0500 Excessive Position Tracking Error
| Item | Description |
|---|---|
| Level | Warning (WARN) |
| Trigger Condition | Absolute difference between target position and feedback position exceeds the project threshold continuously; reference thresholds are 0.2 / 0.5 / 0.8 rad confirmed over 10 ms. |
| Protection Action | Logs the warning only; the fault manager does not actively alter servo output. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Check payload inertia/load, mechanical binding, step position commands, position-loop gains, peak torque capability, and encoder feedback. Severity is WARN in standard reference profiles. |
0x0501 Torque Control Fault
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | Torque feedback exceeds the mechanical protection limit, or torque tracking error is excessive while current output is saturated; reference limits are 180 / 280 N·m over 20 confirmations. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Enabled only on closed-loop torque control projects. Check external mechanical impacts, external back-driving forces, torque sensor calibration, torque setpoint, current saturation limits, and torque-loop gains. |
0x0507 Excessive Velocity Tracking Error
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | Absolute difference between velocity command and feedback velocity exceeds the project threshold continuously; reference thresholds are 500 / 800 / 1000 / 1500 rpm confirmed over 100 / 200 ms. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Inspect mechanical binding or overload, unreleased holding brake, current limit settings, velocity-loop PID gains, encoder feedback, velocity unit scaling, and abrupt velocity steps. |
0x0508 Software Stall
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | Actual speed remains near zero while Iq command remains high continuously; reference low-speed thresholds are 5 / 20 rpm and high-current thresholds are 65% / 95% of peak phase current over 2 s. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Inspect mechanical jamming, excessive load, holding brake release, motor phase wiring, motor health, and current limits. In projects where the stall current threshold is set to 0, this check remains inactive. |
0x0509 Velocity Command Exceeds Upper Limit
| Item | Description |
|---|---|
| Level | Warning (WARN) |
| Trigger Condition | Absolute value of the velocity command exceeds the project-defined maximum motor speed; reported once per excursion and re-armed after the command returns within range. |
| Protection Action | Logs the warning only; the fault manager does not actively alter servo output. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Check host velocity unit scaling, trajectory planning profiles, control mode transitions, and parameter limits; clamp master velocity setpoints within the rated range of the specific model. |
0x050A Runaway / Overspeed Protection
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | Actual speed reaches approximately 1.15 times the project maximum rated speed continuously for ≥ 50 ms. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Check velocity-loop instability, encoder direction/polarity or gear ratio, motor pole-pair parameters, abrupt setpoint jumps, external back-driving loads, and power-stage faults. Always verify feedback polarity before resetting. |
0x050B Excessive Current Tracking Error
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | While PWM and the current loop are active, Id feedback error or Iq command-to-feedback error exceeds a dynamic threshold continuously for ≥ 15 ms; reference enter/exit relative ratios are 0.55 / 0.35. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Eliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists. |
| Troubleshooting | Inspect DC bus voltage, open motor phase wires, power MOSFETs, current sensing, motor inductance/resistance parameters, and current-loop tuning; voltage saturation at high speed can also cause current tracking failure. |
5.7 Communication 0x06
0x0600 Communication Heartbeat Lost
| Item | Description |
|---|---|
| Level | Warning (WARN) |
| Trigger Condition | After receiving the first valid CAN frame, no valid bus frame is received for approximately 500 ms continuously; enabled only in selected project profiles. |
| Protection Action | Determined by project configuration: logs only when set to ACT_REC, or performs controlled deceleration stop when set to ACT_DSTOP (adapting to decelerate-and-hold on brakeless modules). Legacy watchdog logic may also actively Disable the servo upon initial timeout. |
| Clearing Method | Clears automatically via CLR_AUTO once communication resumes; if the servo was Disabled by protection, a new servo Enable command must be sent. |
| Troubleshooting | Verify continuous master transmission, Node ID, baud rate, bus load, cabling, termination resistors, and master real-time task jitter. Do not rely solely on a single non-redundant frame to maintain heartbeat. |
0x0603 CAN Communication BusOff
| Item | Description |
|---|---|
| Level | Warning (WARN) |
| Trigger Condition | CAN controller error counters reach the BusOff state and force a warning report via platform interrupt. |
| Protection Action | Logs the warning only; the fault manager does not actively alter servo output. |
| Clearing Method | Restore physical bus integrity, ensure the servo is Disabled, and execute a fault reset; the platform driver may also automatically attempt CAN controller BusOff recovery. |
| Troubleshooting | Inspect bit rate and sample point settings, 120 Ω termination resistors, CANH/CANL wiring, common ground reference, short circuits, Node ID collisions, EMI noise, and bus utilization. |
5.8 Hardware and Software Limits 0x07
0x0705 Positive Optical Limit Exceeded
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | Positive optical limit input remains asserted continuously for the confirmation time; reference confirmation is 10 ms, enabled only on models equipped with limit switch hardware. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Confirm mechanical safety and clear the positive limit signal, ensure the servo is Disabled, and execute a fault reset. |
| Troubleshooting | Check whether the joint genuinely reached its physical positive stop, sensor mounting and active polarity, sensor supply, wiring, and noise. Avoid commanding further motion toward the positive limit during recovery. |
0x0706 Negative Optical Limit Exceeded
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | Negative optical limit input remains asserted continuously for the confirmation time; reference confirmation is 10 ms, enabled only on models equipped with limit switch hardware. |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Confirm mechanical safety and clear the negative limit signal, ensure the servo is Disabled, and execute a fault reset. |
| Troubleshooting | Check whether the joint genuinely reached its physical negative stop, sensor mounting and active polarity, sensor supply, wiring, and noise. Avoid commanding further motion toward the negative limit during recovery. |
0x0707 Positive Software Limit Exceeded
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | Target position or feedback position reaches or exceeds the positive software travel limit; limit value and source are configured per project (some profiles reference +180°). |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Verify home zero position and mechanical safety, adjust the target position back inside the permitted range, ensure the servo is Disabled, execute a fault reset, and jog out of the limit zone at low speed. |
| Troubleshooting | Active only when software position limits are enabled. Check home offset, multi-turn/single-turn absolute position, gear ratio, unit scaling, travel limit parameters, and commanded target position. |
0x0708 Negative Software Limit Exceeded
| Item | Description |
|---|---|
| Level | Fault (FAULT) |
| Trigger Condition | Target position or feedback position reaches or exceeds the negative software travel limit; limit value and source are configured per project (some profiles reference -180°). |
| Protection Action | Immediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration. |
| Clearing Method | Verify home zero position and mechanical safety, adjust the target position back inside the permitted range, ensure the servo is Disabled, execute a fault reset, and jog out of the limit zone at low speed. |